- Pruducts
- High Voltage(HV)
- P Product series
- Surge Simulator PSUG-20T1
Details
PSUG-20T1 is specially designed for the requirements of electromagnetic compatibility - surge (impact) (SUG) immunity test. It is used to evaluate the performance of power cords and internal connecting wires of electrical and electronic equipment when they are subjected to high-energy transient interference caused by switches and natural lightning strikes.
1. Support multi-channel testing
2. Positive and negative polarity can be switched freely
3. One-button switch between Chinese and English modes
4. Built-in international standard grade parameters
5. Excellent craftsmanship, durable
6. The maximum test voltage can reach 20000V
7. 10.1-inch color touch screen operation
8. Built-in temperature and humidity, time, real-time high-voltage display
9. Phase angle asynchronous or 0~360°free setting
10. Surge test mode full-speed automatic switching
11. Built-in RJ45 interface, remote control (optional)
12. Built-in high-voltage differential probe and current transformer can measure waveform
standard
IEC/EN60664
GB/T17626.5/IEC61000-4-5
ITU K20
ANSIC62.41/45
GB/T16927.1
IEC/EN 61643-1
ITU K44
ITU K45
Product model |
PSUG-20T1 |
Open circuit voltage |
2000V ~ 20000V± 10% |
Voltage resolution |
100V |
Rise time |
1.2μs ±30% |
Duration |
50μs ±20% |
Short circuit current |
1000 A~10000A ±10% |
Rise time |
8μs ±20% |
Duration |
20μs ±20% |
Output polarity |
+,-,+/-, -/+ |
Output impedance |
2 Ω |
Step voltage |
0~20000V |
Interval Time |
5s~9999s |
Test times |
1c~60000c |
Trigger mode |
Manual, external, interval trigger |
Phase synchronization |
0°~359°(50 HZ or 60 HZ) (Synchronous Asynchronous) |
Build-in CDN |
|
Coupling |
1-phase 3-wire coupling |
Decoupling Load |
UAC MAX 240V /16A UDC MAX 220V/16A |
Coupling capacitor |
9μF(L-PE)、 18μF(L-L) |
Coupling resistor |
12 Ω、2 Ω |
Residual pulse voltage at the injection end of the tested equipment |
Not more than 15% of the applied test pulse voltage or twice the rated voltage peak of the coupling/decoupling network |